日产美女牲交动漫在线观看_一级特黄大片欧美久久久久久_一本一本久久a久久精品综合_91精品国产91久久久久久吃药

行業(yè)新聞

當(dāng)前位置:首頁 > 新聞中心 > 行業(yè)新聞

空壓機(jī)在冬季如何進(jìn)行保養(yǎng)?

來源:http://m.lascrucesbarbershop.com/   日期:2020-12-07   瀏覽量:0
TAG:山東制氮機(jī),山東干燥機(jī),山東螺桿鼓風(fēng)機(jī),山東空壓機(jī),山東自動排水器

在寒冷的冬季,由于氣溫較低,空壓機(jī)一旦不注意保養(yǎng)服務(wù)的話,將引起設(shè)備故障。為此,在冬季,因?yàn)殚L時間停機(jī),期間沒有做防凍保護(hù)而造成冷卻器凍裂和啟動時機(jī)體故障等的情況不在少數(shù)。針對此種情況,為空壓機(jī)用戶提出以下幾點(diǎn)空壓機(jī)因冬季保養(yǎng)不當(dāng)而引發(fā)故障的幾點(diǎn)建議:

In cold winter, due to low temperature, once the air compressor does not pay attention to maintenance service, it will cause equipment failure. Therefore, in winter, because of the long-time shutdown and no antifreeze protection, there are not a few cases of cooler cracking and engine failure during start-up. In view of this situation, the following suggestions are put forward for air compressor users due to improper maintenance in winter:

1.停機(jī)較長時間或油濾使用時間較久的機(jī)器,開機(jī)前建議更換油過濾器,以防止剛開機(jī)時因油品粘稠穿透油濾能力下降造成機(jī)體供油不足使得機(jī)體啟動時瞬間發(fā)熱,造成機(jī)體故障;

  1. For the machine that has been shut down for a long time or the oil filter has been used for a long time, it is suggested to replace the oil filter before starting up, so as to prevent the oil from being insufficient due to the viscosity of oil penetrating the oil filtration capacity when the machine is just started up, causing the engine block to heat up instantaneously when it is started up;

    20201207183551.jpg

2.將設(shè)備斷電后應(yīng)用手盤動主機(jī)聯(lián)軸器,應(yīng)轉(zhuǎn)動靈活,對于盤動困難的機(jī)體請不要盲目開機(jī),應(yīng)檢查機(jī)體或電機(jī)是否有故障,潤滑油是否粘稠失效等,故障排除后方可開機(jī);

2. After the equipment is powered off, manually turn the main engine coupling, which should rotate flexibly. For the engine body with difficult turning, please do not start the machine blindly. Check whether the engine body or motor is faulty, whether the lubricating oil is viscous or not, etc. the machine can be started after troubleshooting;

3.空壓機(jī)開機(jī)前應(yīng)確保油溫不低于+2度,若溫度過低,請采用加熱裝置對油氣桶和主機(jī)部位加熱;

3. Before starting the air compressor, ensure that the oil temperature is not lower than + 2 ℃. If the temperature is too low, please use the heating device to heat the oil and gas barrel and the main engine;

4.檢查油位在正常位置,檢查所有冷凝水排放口已關(guān)閉(長期停機(jī)應(yīng)打開),水冷機(jī)組還應(yīng)檢查冷卻水排放口是否關(guān)閉(長時間停機(jī)時此閥門應(yīng)打開);

4. Check that the oil level is at the normal position, check that all condensate drain outlets have been closed (open for long-term shutdown), and check whether the cooling water discharge outlet is closed (the valve should be opened in case of long-term shutdown);

5.兩級壓縮機(jī)器特別是大功率的機(jī)型,停機(jī)一段時間后再次開機(jī)時,需在進(jìn)氣口加入適量潤滑油并點(diǎn)動2-3次,且將油氣桶機(jī)體的注油調(diào)節(jié)閥在剛啟動時要全部打開,運(yùn)行穩(wěn)定后如排氣溫度過低,可調(diào)節(jié)客戶冷卻水閥門的進(jìn)水量來控制溫度,如有必要再根據(jù)實(shí)際溫度情況,通過調(diào)節(jié)注油閥門來控制進(jìn)油量達(dá)到合適的排氣溫度;

5. When the two-stage compression machine, especially the high-power machine, is shut down for a period of time, it is necessary to add appropriate amount of lubricating oil at the air inlet and jog it for 2-3 times, and the oil injection regulating valve from the oil-gas barrel to the body should be opened at the beginning. After stable operation, if the exhaust temperature is too low, the water inflow of the cooling water valve of the customer can be adjusted to control the temperature. If necessary, the actual temperature can be adjusted At the same time, adjust the oil injection valve to control the amount of oil to reach the appropriate exhaust temperature;

6.變頻機(jī)要主意在冬季的排氣溫度,防止過低(主要是長時間低頻運(yùn)行造成排氣溫度過低),根據(jù)排氣溫度調(diào)節(jié)合適的冷卻水水閥的開度,如確實(shí)有必要則可以更換為高溫型熱控制閥芯,避免油品的乳化;

6. Pay attention to the exhaust temperature of frequency converter in winter to prevent too low exhaust temperature (mainly caused by low frequency operation for a long time). Adjust the opening of cooling water valve according to the exhaust temperature. If necessary, it can be replaced by high temperature thermal control valve core to avoid oil emulsification;

7.若已安裝熱回收的機(jī)器,請關(guān)閉熱回收系統(tǒng)的油路閥門,等機(jī)組運(yùn)行正常后再緩慢開啟熱回收系統(tǒng)的油路控制閥門;

7. If the heat recovery machine has been installed, please close the oil circuit valve of the heat recovery system, and slowly open the oil circuit control valve of the heat recovery system after the unit operates normally;

8.以上工作檢查后,空壓機(jī)次開機(jī)應(yīng)作一點(diǎn)動運(yùn)行,檢查運(yùn)行情況及機(jī)體啟動時聲音是否正常。若溫度突變請立即停機(jī)檢查,切勿頻繁啟動機(jī)器,如有必要向機(jī)體內(nèi)添加適量冷卻液。

8. After the above work inspection, the air compressor should be started for the first time by inching to check the operation and whether the sound is normal when the body is started. If the temperature changes suddenly, please stop the machine immediately for inspection. Do not start the machine frequently. If necessary, add proper amount of coolant to the body.

標(biāo)簽:山東空壓機(jī)

上一篇:空壓機(jī)工作時意外停機(jī)的原因有哪些?
下一篇:自動排水器的安裝步驟 你了解多少呢?

日产美女牲交动漫在线观看_一级特黄大片欧美久久久久久_一本一本久久a久久精品综合_91精品国产91久久久久久吃药